Key takeaways
A communication test is a functional check; physical layer conformance is an interface check. A node that transmits and receives perfectly on its own bench will share a bus with dozens of others in the vehicle, where termination, common-mode bias and sample point all shift together. Intermittent error frames usually appear there, not in the laboratory.
Working CAN messages only prove that one pair of nodes talks over one harness. They say nothing about whether the node is compliant on somebody else's bus. Physical layer conformance measures the electrical contract at the interface - differential output level, common-mode level, internal differential resistance, bit timing and loop delay. None of these look abnormal while communication is healthy, yet they decide whether a multi-node vehicle network with long stubs stays stable. Put this test ahead of environmental and EMC work: with a physical layer baseline in hand, any later drift can be classified as degradation, rather than guessed at.
1. Three different questions: communication, immunity, conformance
Projects often report these as one item. They test different objects.
| Question to answer | What is measured | Where the criterion comes from | What passing means |
|---|---|---|---|
| --- | --- | --- | --- |
| Do messages get through | Transmit and receive success, error counters | Bench measurement and vehicle road test | This pair of nodes works on this harness |
| Does it still work under disturbance | Functional status level under applied disturbance | ISO 11452 series and the customer's functional status definition | No failure while disturbed |
| Is the interface compliant | Differential level, common-mode level, impedance, timing | The ISO 11898-2 layer | The node's electrical contract at the bus holds |
Their failure signatures differ too. A broken link is visible immediately. An immunity failure usually shows up as dropouts or resets as soon as disturbance is applied, a path we described in tracing from error counters back to transceiver common mode. A conformance failure shows nothing in the laboratory at all; it surfaces on the vehicle bus as intermittent error frames.
That is exactly why it gets skipped: no visible failure on the day, so nobody books time for it.
2. Conformance is an interface contract, not a vehicle performance figure
Physical layer conformance is not a performance metric, it is a precondition for interoperability. It answers a narrow question: does this node's bus interface sit inside the window defined by the standard.
Narrow, but consequential. A node with a low differential swing, a shifted common-mode level or an out-of-window internal resistance behaves perfectly on its own, because the one or two nodes beside it compensate. On the vehicle, dozens of nodes share one bus; termination in parallel, common-mode bias and sample point all shift together, and every compensation relationship is recalculated.
The symptoms then look like an environmental failure or thin immunity margin, while the root cause sits in the physical layer. The same gap appears in parts that pass every test and still fail on the vehicle: between a compliant part and a compliant vehicle there is not a stricter condition, but the deviation that used to be compensated away.
So conformance data has one use nothing else replaces - it is the baseline. With a baseline, later drift is degradation. Without one, any out-of-window reading is a guess.
3. Six parameter groups, each covering one thing
The ISO 11898-2 layer covers the high-speed CAN medium access unit. Its parameters fall into six groups. The table gives the division of labour, not the numbers: limits live in the standard text and vary with transceiver type and with CAN FD support, so the applicable revision and the technical agreement always govern.
| Parameter group | What it constrains | Where an out-of-window value shows first |
|---|---|---|
| --- | --- | --- |
| Differential output voltage, dominant and recessive | Differential swing in both states, which decides whether the receiver can separate the two bits | Rising error rate with long stubs or many nodes |
| Common-mode output voltage | Bus-to-ground common-mode bias in both states | Common-mode current and reduced immunity margin once networked |
| Internal differential resistance and termination | The load the node presents, including split termination values | Network termination drifts from design, reflections and ringing increase |
| Bus pin leakage and input capacitance | How "heavy" the node is on the bus, amplified by node count | Fails with many nodes, works again with a few |
| Bit timing and loop delay | Whether oscillator tolerance, propagation delay and sample point align | Sample point drifts with temperature or voltage, intermittent error frames |
| Bus pin withstand and transient robustness | Margin against assembly, jump-start and ESD transients | Field returns that cannot be reproduced in the laboratory |
The last group deserves a note: it tends toward destructive testing, requires a different sample state from ordinary electrical parameters, and should not be quietly appended to the same batch of samples as a free extra.
4. Four readings that are easy to get wrong
First: termination is a network parameter, not a node parameter.
One terminator at each end of a high-speed CAN bus, with the parallel value landing near the design figure, is a network-level convention - the industry practice is one 120 ohm resistor at each end, subject to the applicable revision and the network design. Using a network reading to prove a single node compliant is a logical error; it proves the network works. What a node must be measured for is its internal equivalent differential resistance and whether split termination follows the design.
Second: common-mode level must be read in both states.
Reading only the dominant state is a recurring omission. The common-mode windows for dominant and recessive are not the same, and the recessive window is often the tighter interval for receiver discrimination. A node with a clean dominant reading and a recessive value outside the window will still misbehave once networked, while the report carries a single line saying common-mode level is normal.
Third: matching the baud rate is not the same as passing bit timing.
Bit timing is the superposition of oscillator tolerance, transceiver loop delay and harness propagation delay. A sample point measured on a short bench harness moves on a vehicle harness, and a value that passes at room temperature can move at the temperature extreme. Checking baud rate alone checks one of three things.
Fourth: poor differential symmetry surfaces first as radiated emission.
Once the differential driver is asymmetric, a common-mode component appears and the bus harness becomes an effective antenna. Adding filters or changing shielding at that point leads in circles, because the source is driver symmetry. The path connects to the difference between the two conducted emission methods: establish whether the excess is differential or common mode, then decide whether to change the interface or the harness.
5. Five columns the outline must contain
Readings are extremely sensitive to conditions. If conditions are not written down, two data sets cannot be compared.
| Column | Why it is mandatory | What happens without it |
|---|---|---|
| --- | --- | --- |
| Node state | Powered, sleeping and bus-fault states read differently | Each side measures one state and the conclusions cancel out |
| Termination configuration | Whether internal termination is enabled and external termination is fitted | The same node yields two resistance values |
| Measurement point and probe method | Transceiver pin, connector terminal and harness end are not equal | Data cannot be aligned to the standard window |
| Applicable revision and class | Transceiver type and CAN FD support decide the window | Judged against the wrong class, a pass reads as a fail |
| Harness and topology | Loop delay and stray capacitance enter the result directly | Bench pass, vehicle fail, no explanation |
One sequencing point sits outside the five columns: run electrical parameter items before transient and withstand items. Transient items can accumulate damage, and returning to electrical parameters afterwards measures an already discounted value.
6. Why it belongs before environmental and EMC work
There is one reason: environmental testing changes exactly the things physical layer parameters depend on.
Temperature cycling acts on solder joints and interfaces, damp heat on dielectrics and surface state, vibration on contact resistance and terminal preload, salt spray on plating. All of it eventually lands on differential resistance, leakage and bit timing. Measure conformance first and those changes become measurable degradation; measure it last and an out-of-window reading cannot be separated from insufficient design margin.
The second link is on the immunity side. Once a physical layer parameter leaves the window, the transceiver no longer operates at its design point and immunity margin shrinks with it. Adding countermeasures blindly at that stage often aims at the wrong target - the same logic we set out in why bulk current injection and radiated immunity are not interchangeable: confirm the operating point before discussing margin.
Skip the baseline step and what remains is a report that says passed, plus a set of vehicle-level symptoms nobody can explain.
7. A few plain words
Most conformance failures are selection and configuration errors, not design errors. Whether internal termination is enabled, the split termination values, the common-mode choke selection, oscillator tolerance - change any one and the result often moves substantially. Read the configuration list before touching the circuit.
Do not treat "the network works" as a conclusion. A vehicle road test passing means this combination works on this vehicle; it does not mean the node is compliant on any bus. The two are frequently confused in procurement discussions, and when a problem appears both sides turn out to be compliant with nobody accountable.
The reader of a conformance report is the counterpart's electronics engineer, not procurement. Stating measurement points, node states and the applicable revision is worth more than an extra page of conclusions.
When TMC LAB takes on this kind of commission, the parameter scope, measurement points and sample states go into the outline before scheduling, so that incomparable readings are not discovered at the end. All conditions point to the applicable standard revision and the customer technical agreement, with no numbers presumed.