Key takeaways
The entry point for mechanical loads is not "how much vibration", but "which mounting location does this part belong to". The location group sets both the spectrum and the shock conditions; a resilient mount is not grounds for a lower category, and a part spanning two locations cannot be averaged. A bench spectrum is a derived quantity - shape, bandwidth, level and duration move together, and changing one rewrites which failure mode is exercised.
The condition tables in the mechanical load part are organised by vehicle mounting location, not by product category. Asking "how much vibration does this board need" therefore starts in the wrong place - first establish where the part is mounted and along which route the excitation arrives, and only then does a condition have a source. Get the location wrong and the spectrum shape, axes, fixture and verdict all become irrelevant: the report looks complete while answering a different question. The four layers below cover the grounds for location judgement, three situations where it commonly goes wrong, how bench spectra are derived, and the fixture boundary.
1. Conditions follow location, not product
ISO 16750 is split by stress type: electrical loads, mechanical loads, climatic loads and chemical loads each occupy a part, with mechanical loads in Part 3. GB/T 28046 mirrors it part by part; the adoption relationship and revision years are stated in the standard foreword, and a separate article covers how to line the two up.
Inside ISO 16750-3, the first task is not reading a spectrum but finding a location. The part groups its conditions by mounting area - powertrain and engine bay, unsprung mass and chassis, passenger compartment, doors and closures - each with its own random vibration spectrum, sinusoidal sweep level and mechanical shock conditions, while transport and handling cases are normally added by agreement. Group names, clause numbers and the conditions themselves should be taken from the standard text; no magnitudes appear here.
Location attribution is thus a judgement that needs evidence, not a checkbox. Three criteria only: which structure the part is finally fixed to, along which route the excitation arrives, and whether any isolator or flexible element sits in between.
| Ground for judgement | What it settles | Consequence of getting it wrong |
|---|---|---|
| --- | --- | --- |
| The structure the part is finally fixed to | The location group that structure belongs to | The whole condition set is misaligned and no longer shares a source with the vehicle |
| The route the excitation arrives along | Whether segments are needed and whether the part spans groups | Only one segment is tested and the other carries no coverage |
| Presence of isolators, subframes or flexible links | Which side the isolator belongs to | A resilient mount is used to justify a lower category, i.e. conditions relaxed unilaterally |
| Whether it is an add-on, modified or aftermarket part | Whether the OEM location table covers it | Without an agreement, only the unfavourable location can be applied, and the basis must be stated |
The third row is a frequent source of rework. An isolator changes the response, not the excitation; treating it as grounds for a lower category swaps "what the part feels" for "what the structure applies", and those are two different columns on a report.
2. Three situations that are commonly misjudged
Situation one: parts with resilient mounts. The usual mistake is to take the measured response of the part itself and map it onto a lower location group. The correct basis is the structure the bracket is fixed to - the isolator is an element in the transmission path and does not justify a lower category unless the technical agreement says so explicitly. If conditions really are to be set from the isolated response, put the basis in the agreement and the outline rather than leaving it in verbal discussion.
Situation two: parts spanning two locations. A harness running from the passenger compartment into the engine bay, a controller straddling the bulkhead, a connector exposed in the front bay while the body sits inside. The usual mistakes are averaging the two segments or testing only the milder one. The correct approach is to map each segment to its own location, or, where the sample cannot be split, apply the harsher segment to the whole item and state the reason in the outline. Averaging dilutes both, so a failure belonging to either segment is never fully exposed. When testing in segments, restraint around the boundary point is often where failure starts, and the verdict items must reach it.
Flexible structures have a further consideration of their own: if restraint spacing, branch routing and length allowance differ from the vehicle, the failure set changes too. The harness vibration and wear article covers how restraint and observation items map onto one another.
Situation three: add-on parts, modified brackets and aftermarket items. The OEM location table does not cover these, because they have no established mounting point on the vehicle. Without an agreement the only defensible option is the unfavourable location, with the basis stated in the report; do not lift conditions from a similar OEM part, since visual similarity does not mean the excitation path is the same.
| Situation | Common mistake | Correct approach |
|---|---|---|
| --- | --- | --- |
| Parts with resilient mounts | Mapping the part's own response onto a lower group | Judge by the structure the bracket sits on; an isolator is not grounds for a lower category unless agreed |
| Parts spanning locations | Averaging the segments, or testing only the milder one | Map each segment, or apply the harsher segment throughout with the reason in the outline |
| Add-on parts and modified brackets | Copying the table for a similar OEM part | The OEM table does not cover them; add an agreement, or use the unfavourable location and state the basis |
3. A bench spectrum is derived, so "harsher" is not a comparable dimension
The spectrum on the bench is not a curve the standard invented; it is derived from vehicle road-load data by damage equivalence, with measured excitation statistically processed and accelerated into a shape and duration that can be reproduced stably. Once that is clear, comparisons such as "their spectrum is harsher than ours" fall apart: unless the input shares a source - same vehicle, same location, same measurement point, same derivation method - the two spectra do not live in the same coordinate system.
That brings a hard constraint: shape, bandwidth, overall RMS and duration are a bound set; change one and the others must follow. Shortening the duration forces the level up, and a rise in level does not scale every failure family equally. Failures driven by large displacement at low frequency - harness swing, low-frequency bracket resonance, loosening of heavy connections - and failures driven by small displacement at high frequency - solder joints, pins, small-scale connections - respond quite differently to the same increase. "Harsher" therefore does not mean "safer"; it may move the focus from one failure family to another.
How to read a spectrum - shape, breakpoints and what the overall RMS corresponds to - is covered in the sine sweep versus random vibration article, and the division of labour between the three stress types in the GB/T 28046.3 mechanical load piece. This article deals only with where a spectrum comes from and therefore how it cannot be compared.
| Source of the spectrum | Who defines it | What the report must state |
|---|---|---|
| --- | --- | --- |
| Standard location spectrum | Standard part and location group | Part, revision year and location group, with clause number |
| OEM specification spectrum | Customer specification | Specification number, revision and clause, noting whether it supersedes the standard |
| Measured vehicle spectrum | Agreed by both parties | Acquisition conditions, measurement points and derivation method |
| Agreed spectrum in the technical agreement | Technical agreement | Agreement number and revision, with differences from the standard |
The fourth row is often missed. When an agreed spectrum differs from the standard, a report saying only "tested to the standard" leaves the reviewer unable to tell what was actually applied - traceability given away for free.
4. Fixture and mounting boundary: the gate on acceptance
With the conditions and spectrum right, one gate remains: the fixture. Bench boundary conditions are not the same as vehicle installation, and the differences cluster in five places: fixture stiffness, contact surfaces and fastener torque, added mass, harness routing and restraint spacing, and the orientation and centre of gravity of the sample on the fixture.
These differences are not theoretical; they leave evidence. Change the fixture on the same sample and the peak of the sweep curve moves. A shift to the left means overall stiffness has been pulled down by the fixture, a shift to the right means it is over-constrained; either way the resonance being read is no longer the one on the vehicle. Fixture drawings and vehicle mounting drawings therefore belong in the test record together, and only when they line up does the report hold.
Two conventions must also be written down.
Control point versus monitoring point. The control point follows the test specification and keeps the applied level within the requirement; the monitoring point answers how much the part itself is receiving. Different positions, different readings - they must not be collapsed into one number. Monitoring points usually sit at critical locations or where failures are expected, and the reason for the choice should be recorded.
Sequential single axis versus simultaneous multi-axis. Running three axes one after another is not the same as loading them together. Coupled failures in multi-axis parts - where displacement in one direction changes the constraint in another - appear only under simultaneous loading. Whether multi-axis is required depends on the location group, the part and the agreement; where the capability is not available, state plainly that axes were applied sequentially rather than implying equivalence with "three axes completed". Temperature, humidity and vibration acting together is a different arrangement again: the three-integrated article covers interaction effects under combined stress, which is not the same question as multi-axis loading.
One final item is often dropped: in-situ monitoring during vibration. Intermittent opens, contact resistance steps and dropped communication frames appear only while the sample is moving, and a post-test re-check reads normal every time. Whether signals can be taken in situ depends on feedthrough provision and on whether the part is powered, and that has to be settled at the outline stage - it cannot be recovered afterwards.
A few plain words
Before submitting samples, write down the answers to three questions; it is worth far more than the five words "run vibration and shock". Where is the part mounted, who supplied the spectrum, and how will the fixture be built. With all three answered, the conditions follow naturally; with any one missing they can only be guessed, and by the time a rework happens the sample has already been through a round of stress.
When TMC LAB takes on mechanical load commissions, the location attribution, spectrum source and fixture plan are written into the outline as three columns, with the handling of spanning parts and isolated parts marked separately, and testing is scheduled only after confirmation. Levels, bandwidth and duration follow the standard clauses, the OEM specification and the technical agreement; no values are preset at the outline stage.
Bring the vehicle mounting drawing, the previous report and the page reference for the relevant clause in the technical agreement, and the location attribution is usually settled on the spot. The ordering of IP, climatic and mechanical items has its own logic - the environmental reliability checklist and the IP rating re-check are useful when planning it, and the vibration service scope is set out on the vibration testing page. Scheduling is arranged per project; you can state your expected delivery date when submitting samples, and we will confirm a feasible plan against the current schedule and report progress at each milestone.



