A power module is a package rather than a single device - die, bond wires, die attach, substrate and baseplate are stacked together. Power cycling loads the connections near the die, temperature cycling loads the large-area joint between substrate and baseplate, and neither report substitutes for the other. Degradation shows up first in electrical and thermal readings, with functional failure arriving at the end, so the criterion can only be a drift measured at identical current, identical junction temperature and the same point against the initial value, with the threshold set by the technical agreement. Readings taken at the module terminals average the parallel die, so the first one to degrade is averaged away.

A power module in a motor controller usually fails at the end of the chain, not at the start. One module is not one device: several die are paralleled on a single substrate, separated by bond wires, die attach, substrate and baseplate. Once those layers degrade the vehicle still drives and the report still says the function is normal; only electrical and thermal readings taken at identical conditions against the initial value show it. By the time over-temperature protection trips, output is derated or the device is destroyed, the chain is already at its far end.

1. Four joints, not one device

The die itself rarely fails first. What fails first is the material that connects it outwards.

JointWhat it connectsMain stress sourceHow it degradesVisible at the terminals?
---------------
Die metallisation and bond wiresDie surface to terminalThermal expansion mismatch between aluminium and silicon, repeated temperatureCracks and lift-off at the wire rootOn-state voltage drifts up, function unchanged
Die attachDie to substrate copperThe die's own junction swingVoids grow, delaminationThermal resistance rises, function unchanged
Substrate to baseplateCeramic substrate to baseplateCase and baseplate temperature swingLarge-area delamination, ceramic micro-cracksThermal resistance steps, insulation drops
Baseplate to heatsinkBaseplate to cold plateClamping force and repeated temperatureThermal interface material pumps out and driesSystem thermal resistance creeps up

The four layers are driven by different stresses, and that is exactly why this family of tests goes wrong: test one layer with another layer's conditions and the result says nothing.

Take the bonds first. Aluminium and silicon differ in thermal expansion by an order of magnitude, so any temperature change concentrates stress at the wire root. A micro-crack appears first, then the whole loop lifts, with the path still connected through a smaller contact area.

Then the die attach. Solder creeps and coarsens when held near its melting range, and voids grow from the ones left by the process. Silver sintering resists this far better, but the stress is pushed elsewhere - the failure location moves, from the attach to the die metallisation and the bond wires. Changing the joining material is not a small durability gain; it relocates the criterion.

2. Power cycling and temperature cycling load different layers

ConditionWhere the temperature swingsLayer mainly loadedReading to watch
------------
Power cyclingJunction swing large, case swing smallBond wires and die attachOn-state voltage, junction-to-case thermal resistance
Temperature cyclingCase and baseplate swing, die barely self-heatsLarge-area joint between substrate and baseplateThermal resistance, ultrasonic scan
Thermal shockSame, with faster transferSame, with rate-dependent interface stressSame
High-temperature operating and storageSteady, powered or unpoweredPackage materialsFunction and parameters

The judgement here is a single sentence: a number of cycles between a low and a high temperature says nothing about the junction swing.

The chamber moves case and baseplate temperature and loads the outer joints of the package. How hard the bond wires and the die attach are hit depends on the die's own junction swing, which is set by conduction and switching loss, conduction time and cooling. Both are called temperature cycling, yet they are two different tests. To describe power cycling, load current, conduction time, duty cycle and cooling condition must be written down, otherwise nobody reproduces the same junction swing.

The difference between the two profiles is covered separately (temperature cycling is not thermal shock), and how the condition tiers are set is in thermal shock conditions.

3. The criterion can only be a drift

ReadingWhat it reflectsWhy identical conditions and an initial value are mandatoryWho sets the threshold
------------
On-state voltage or on-resistanceState of bond wires and die metallisationIt has a temperature coefficient and follows current and junction temperatureCustomer technical agreement
Junction-to-case thermal resistanceVoids and delamination in the die attachDepends on method (transient or steady state) and on the fixtureCustomer technical agreement
Body-diode forward voltageThe same layer through another entry pointAlso follows temperature and currentCustomer technical agreement
Insulation resistance and withstand voltageSubstrate, ceramic and encapsulationAffected by humidity, contamination and test voltageStandard and agreement

On-state voltage on its own means almost nothing. It has a clear temperature coefficient, so at the same current a warmer junction reads higher; die from different lots and different measurement currents are not comparable. The criterion is therefore not a limit value but a drift from the initial value at the same current, the same junction temperature and the same point.

Thermal resistance is the same story. A transient curve separates the contribution of each layer, a steady-state figure gives one total; change the fixture or the interface material and the total moves. The criterion has to state which method was used, otherwise two thermal resistance numbers compared across reports compare fixtures.

On the threshold column, the standard gives the method and the conditions, not your drift limit. That belongs in the technical agreement, and "drift beyond the agreed value counts as degradation" is far more useful than "function normal, passed".

Whether test hours can be converted into service life depends on the assumptions behind an acceleration model (why hours do not extrapolate into years), and this family deserves a careful look: what is accelerated is the junction swing, not the chamber temperature.

4. Measuring the terminals measures an average

MethodWhat it showsWhat it hides
---------
Reading at the module terminalsThe equivalent of all paralleled dieThe one that degraded first
Group-wise gate driveThe equivalent of each groupIndividual die within a group
Probe on each die after openingSingle dieRequires destroying the sample or a dedicated fixture
Infrared or camera after openingHot spot distributionNot possible without opening
Transient thermal structure functionLayer-by-layer contributionNeeds known loss and a good fixture

Paralleled die self-balance through the positive temperature coefficient of on-state voltage: whichever runs hotter reads slightly higher and takes slightly less current. Once a bond lifts, that die's equivalent resistance rises, it takes less current, and the others make up the difference - their junctions run hotter, and degradation from then on takes a faster path.

At the terminals this produces a misleading picture: the overall reading moves a little, still looks in range, while a local hot spot on one die is already heading for the protection point. That is what "the terminals cannot see the first one to fail" actually means.

Set this next to the thermal problem in domain controllers: there the question was whether the heat source sits inside or outside, changing how chamber temperature relates to junction temperature. Here the heat source is on the die itself, and there is a group of them, so the reading has to reach the individual die.

5. Five columns in the outline

ColumnWhat to writeWho decides
---------
Product formModule or discrete, die material, number of parallel die, permission to openCustomer
Cycling type and swing basisPower or temperature cycling, how the junction swing is measured and controlledStandard method and customer agreement
Criterion and thresholdDefinition of the drift, the measurement point, the acceptance tier, per-die or terminalCustomer technical agreement
Monitoring and samplingIn-line readings, thermal resistance checkpoints, ultrasonic scan samplingConfirmed by both sides
Post-failure handlingWho opens the package, whether cross-sectioning is done, sample ownershipCustomer and laboratory

The laboratory decides only the execution details. The other four columns come from the standard text or from the customer agreement. The value of a report in this family rests on whether "drift against what, measured under which conditions" is written down, not on the equipment model.

For the part structure and environmental conditions see ISO 16750 and the mapping to GB/T 28046; German projects layer LV 124 on top. The entry point for this side of the work is materials and failure analysis, with service pages for temperature cycling and vibration. On the high-voltage side the module picks up an additional family of electrical load behaviour (electrical loads on the high-voltage side).

6. A few plain words

Before sending samples, answer three questions: with which reading would you see that this module has degraded, are you measuring the die or the terminals, and is your cycle swinging the junction or the chamber? If all three have answers the outline can be written straight away. If not, run one round of baseline measurement first - otherwise what comes back is a report saying the function is normal, and that report proves nothing.

When TMC LAB takes on this kind of commission, the baseline readings and the criterion go on the front of the outline: how the initial value is taken, how the same conditions are reproduced, how much drift counts as degradation, and who opens the package. Leave those four open and the cycling can run as long as it likes - it still yields a temperature curve with no reference.

Scheduling is arranged per project; you can state your expected delivery date when submitting samples, and we will confirm a feasible plan against the current schedule and report progress at each milestone.

Related Q&A

Related questions

Frequently asked questions on the same topic. The first paragraph of each answer is the conclusion.

Why is it not enough to write a life test as a number of cycles between a low and a high temperature?
Because that sentence says nothing about the junction temperature swing. The chamber moves the case and baseplate temperature and mainly loads the large-area joint between substrate and baseplate, while how hard the bond wires and the die attach are hit depends on the die's own junction swing, which is set by conduction and switching loss rather than by the chamber. Write the same words into two differently built tests and one report exercises the outer joints of the package while the other exercises the joints next to the die; the conclusions cannot be swapped. To describe power cycling, the load current, conduction time, duty and cooling condition have to be written down as well, otherwise nobody reproduces the same junction swing.
The functional test passed, so why say the module has degraded?
Because degradation of these joints starts as more resistance and more thermal resistance, and functional failure sits at the far end of that chain. A crack or lift at the bond wire root leaves the path intact, with on-state voltage a little higher at the same current than the initial value. Voids in the die attach leave the device switching normally, with junction temperature a little higher at the same loss than the initial value. Neither makes a functional test fail until a local hot spot pushes the junction into protection, which is why the criterion for this family has to be written as a drift rather than as pass or fail.
How is junction temperature measured, and why not just use a thermal camera?
A camera sees the surface, and the die sits inside the package, so without opening it you read case or baseplate temperature only. The established approach back-calculates from a temperature-sensitive electrical parameter: measure on-state voltage or body-diode forward voltage at a known small current, calibrate that against temperature first, then use it as a thermometer under real operating conditions. The method requires a small measurement current, fast sampling, and calibration under the same conditions as the measurement. Infrared or camera inspection after opening the package is a different job - it locates a hot spot rather than providing the criterion.

These answers share the same data source as the FAQ page.

Have a testing requirement? Send us your product details

Tell us the product model and test requirements. Our engineers will map out the test plan, the applicable standards and the item combination, and provide a quotation reference. The more specific the request, the sharper the answer.

  • Free scoping of the test plan and standards
  • Pre-scan testing during R&D to cut rework cost
  • On-site visits and witnessed testing supported
  • Scheduling per project, with progress updates at each milestone

Received — we will contact you shortly and follow up with a test plan and quotation.

By submitting you agree to be contacted by phone or email. Scheduling follows the project’s actual availability and is subject to mutual confirmation.

13510907826
Call