Key takeaways
Insulation aging is not a single direction. When plasticiser and small molecules leave, the compound hardens and cracks; when media enter, or the crosslink is underdeveloped, it softens, turns tacky and shrinks back. The criteria differ too: tensile strength can rise before it falls, elongation drops first, so strength alone lets a brittle part pass, and insulation resistance or withstand voltage often still pass while the compound is brittle. Sampling must include the crimp zone, the bend and the section next to heat sources, otherwise the locations where failures actually occur sit outside the criterion.
"The harness is gone" covers two opposite failures. In one, the insulation is brittle enough to snap when bent; in the other it is tacky, soft, and has shrunk back from the terminal leaving a short length of bare conductor. The first is plasticiser and small molecules leaving the compound. The second is media getting in, or a crosslink that never developed. The number you measure and the step you change are not the same in the two cases.
Both can also pass an electrical test without any visible sign.
This piece covers the insulation body only. Abrasion is mechanical wear, covered in harness vibration testing; cracking driven by structure plus media is covered in stress cracking in plastics; shrinkage of a seal after media extraction is covered in compression set and media compatibility of seals. Sampling positions and criteria differ across all three, and mixing them produces wrong conclusions.
1. Separate hardened from softened
Insulation is not a single material. On the same harness, PVC, cross-linked polyolefin, silicone rubber and thermoplastic elastomer age along different paths, and the visible direction can reverse.
| Insulation material | Dominant aging path | Direction | What you see on the harness |
|---|---|---|---|
| --- | --- | --- | --- |
| PVC | Plasticiser loss by volatilisation and migration, dehydrochlorination | Hardens and embrittles first, may turn tacky later | Fine cracks on bending, whitened fracture, stiff end near the terminal |
| Cross-linked polyolefin | Oxidative chain scission, copper-catalysed degradation, water trees | Embrittles, locally powders | Powdering when stripped, abnormal discolouration of the conductor |
| Silicone rubber | Migration of small molecules from incomplete cure, high-temperature cleavage | Either direction is possible | Tacky dust-attracting surface, slow rebound |
| Thermoplastic elastomer | Soft-segment oxidation, swelling in oils | Mostly softening and sagging | Swollen section at oil contact, drop in peel force |
Hardening usually means something left the compound; softening usually means something entered it, or the compound was never cured far enough.
Those two sentences cover most shop-floor judgement calls. The exceptions need the sampling position and the contact media to settle: silicone softening often traces to incomplete cure rather than any medium, while PVC from which a medium has extracted plasticiser shrinks and hardens, which reads like faster aging than it is.
Hardening is also not uniform. The crimp zone near the terminal, the run next to a heat source or bundled against another hot circuit, and the tight bend radius always go first. Cutting a section from the middle of the run and finding it normal often only proves the middle has not reached that stage yet.
2. The criterion is not "it still looks fine"
Insulation aging is quiet on electrical measurements. Insulation resistance and withstand voltage commonly still pass while the compound is brittle, because no crack has bridged and creepage distance has not yet shrunk to a problem. An electrical pass therefore does not replace a mechanical criterion, and visual inspection does not either, since tackiness and shrink-back are easily written off as assembly issues.
| Criterion | What it answers | What it misses |
|---|---|---|
| --- | --- | --- |
| Tensile strength retention | How much load capacity remains | The early stage, where strength can rise before it falls |
| Elongation at break retention | Whether it can still bend and absorb deformation | Only meaningful against unaged parts of the same lot |
| Insulation resistance and withstand voltage | Whether current leaks now | Brittleness, tackiness and shrink-back that have not bridged |
| Visual check and cross-section | Cracks, powdering, shrink-back | Depends heavily on sampling position and reader experience |
Elongation falls before tensile strength.
While plasticiser is only starting to leave, the compound stiffens and the strength reading can sit above a new part; once it truly embrittles, strength drops quickly. Measuring strength alone, or at a single point in time, returns a pass across exactly that window.
Retention must be referenced to unaged parts from the same lot, not to the catalogue typical value. The catalogue figure is a typical value at delivery and lots already scatter around it, so comparing an aged part against it folds lot variation into the aging number. The same logic is laid out in why data before and after a test do not agree.
3. Three accelerators beyond chamber temperature
Insulation temperature is not chamber temperature. A conductor carrying current heats itself, so a loaded run and an unloaded run expose the insulation to different temperatures; because aging is exponentially sensitive to temperature, that gap grows over time. Whether the run is loaded is therefore part of the condition, not an optional detail.
| Accelerator | How it acts | What the plan must state |
|---|---|---|
| --- | --- | --- |
| Conductor self-heating | Insulation runs hotter than the chamber | Load current and energisation mode, or explicitly unloaded |
| Bending and fixing | Residual stress at the bend adds to aging | Bend radius, fixing points, routing |
| Media contact | Extraction or swelling by oil, coolant, cleaner | Media name and contact mode |
| Crimp zone | Local stress plus copper-catalysed oxidation | Whether sampling includes the crimp |
Media contact is where plans get vague. "It has seen engine oil" and "immersed in a specified medium at a specified temperature" are different conditions with different criteria. Reagent families and contact conditions are written per chemical load in GB/T 28046.5 and are not repeated here.
On extrapolating duration: extending time at one temperature, or shortening it at a higher temperature, requires proof that the failure mechanism has not changed. Once the mechanism shifts, for example from plasticiser migration to oxidative scission, extrapolation no longer holds. That is set out in what a test duration can represent; here one line is enough: extrapolation rests on an unchanged mechanism, not on a good curve fit.
4. Why the terminal end fails first
Two causes overlap.
The first is shrink-back. Under heat history and crimp stress the compound relaxes, the end retreats and a short length of conductor is exposed, reducing creepage distance and bend allowance together. The second is copper catalysis: copper ions accelerate oxidation of polyolefin insulation, and the crimp zone is exactly where stress concentrates, so both conditions meet in the same short length.
Shrink-back is not a short crimp; it is the compound relaxing under temperature and stress.
Measure it after the same temperature history has been applied, not on a part straight off the line, where relaxation is still incomplete.
The practical consequence is sampling position. A plan that says "take one section from the middle of the run" places the crimp zone, the bend and the heat-adjacent run outside the criterion entirely. The link between part count and sampling points is covered in sample quantity and how representative a verdict is.
5. Five columns the test plan must fill
| Column | What to state | What it costs when omitted |
|---|---|---|
| --- | --- | --- |
| Temperature class and loading | Limits, dwell, transition; load current and energisation | Insulation temperature differs from chamber temperature, results not comparable |
| Specimen state and routing | Bend radius, fixing points, whether the crimp is included | The locations that actually fail sit outside the criterion |
| Media contact | Media name, contact mode, temperature | "It has seen oil" cannot be reproduced |
| Criteria and retention basis | Which items, compared against which parts, at which positions | Comparing to catalogue values turns lot variation into aging |
| Sampling and part count | How many positions per section, how destructive items are counted | Destructive items consume the parts later items need |
Of the five, media contact and the retention basis are the two most often merged into "per the standard". But GB/T 28046 and ISO 16750 supply application conditions and judgement grades; they do not know your routing, which medium the run touches, or where the crimp sits. Those come from the technical agreement. Criteria for the insulation body and its sampling rules usually live in the material specification and the customer agreement, which is the order the request form on the materials and component testing side should follow.
A few plain words
- Decide the direction first, then the conditions. Hardening sends you to formulation and temperature history; softening sends you to media and cure state. The corrective actions point in opposite directions.
- An electrical pass is not proof the insulation has not aged. By the time elongation has dropped, insulation resistance commonly still looks good.
- A single strength reading is easily fooled by the rise-then-fall pattern. Measure retention, against unaged parts from the same lot.
- Sample the crimp zone, the bend and the heat-adjacent run separately. Mid-run data does not answer questions about those places.
- Write the full media list: coolant, brake fluid, washer fluid, cleaner and urea sit alongside engine oil.
- TMC LAB confirms sampling positions and the media list before discussing condition grades on harness programmes, because the reverse order makes later results hard to attribute.
Scheduling is arranged per project; you can state your expected delivery date when submitting samples, and we will confirm a feasible plan against the current schedule and report progress at each milestone.