Key takeaways
A chemical resistance test runs unloaded, so it can only answer whether material and medium are compatible; stress cracking needs residual stress, medium and time-temperature together. The four sources of residual stress are gate and flow orientation, wall-thickness steps, demolding and ejection, and assembly preload or secondary operations, and each leaves a locatable signature. The medium does not corrode the part - it lowers the threshold for cracking, so "no visible deformation after soaking" is not a criterion. Evaluate with specimens under a known strain and read initiation time and critical stress, and separate fracture types by origin, plastic deformation and crack pattern. Relieve stress first, then discuss another grade or another material.
A chemical resistance soak that passed, followed by a part that cracked months later, is not a contradiction. Stress cracking in plastics needs three conditions at the same time: residual stress left by moulding, a medium able to enter the surface, and enough contact time at temperature. A conventional chemical resistance test supplies the medium but not the stress - it answers half the question.
The conclusion usually heard on the floor is "this material cannot handle the cleaning agent". Put the cracked part under polarised light and the crack sits exactly opposite the gate, where the fringe bands are dense enough to shine. The medium did not change, the grade did not change; what changed is the stress at that location.
1. Why a chemical resistance test cannot catch stress cracking
Most chemical resistance clauses follow one skeleton: the part or a coupon contacts a specified medium, stays at a specified temperature for a specified time, and is then checked for appearance, dimensions, mass and performance (both GB/T 28046 and ISO 16750 are built this way).
There is no loading step in that skeleton. The sample carries no working load, and preserving moulded-in stress is not a requirement. Flat coupons are often cut from finished parts, which releases part of the stress before the test even starts.
A real part is different:
- It leaves the mould carrying residual stress, higher near the gate and at the end of flow;
- Assembly adds preload: interference at snap fits, hoop stress from thread-forming screws, press fits and inserts;
- Some locations work near yield for years without showing visible deformation.
| Item | Conventional chemical resistance test | Stress cracking evaluation |
|---|---|---|
| --- | --- | --- |
| Stress state of sample | No applied stress, residual stress not controlled | Known constant strain or stress applied |
| Focus | Medium type, temperature, duration, appearance and properties | Stress-time combination at which cracking starts |
| What the result reads | Whether this material survives this medium | How far this stress level lowers the threshold |
In one line: chemical resistance answers "compatible or not", stress cracking answers "how much stress can it still carry". The first is material screening, the second is a structural verdict. Neither report substitutes for the other.
2. Where residual stress comes from: four sources, all locatable
Residual stress is not an abstraction; it has a location on the part. Checking these four places is more useful than arguing about grades.
| Stress source | Where it shows on the part | Field signature | Mitigation |
|---|---|---|---|
| --- | --- | --- | --- |
| Gate and flow orientation | Opposite the gate, end of flow, weld lines | Dense fringes, crack aligned with gate position | Move or add gates, lower injection speed and packing |
| Wall-thickness step | Thick-to-thin transition, rib roots, boss roots | Sink mark and crack in the same place | Even out wall thickness, add transition radii |
| Demolding and ejection | Around ejector marks, deep side walls | Ejector whitening, local gloss, light scuffing | More draft, adjusted ejection force and mould temperature |
| Assembly preload and secondary operations | Snap-fit roots, screw bosses, ultrasonic weld lines, insert perimeters | Whitening right after assembly | Reduce interference, redesign bosses, keep weld lines off load paths |
The first two come from moulding, the last two from assembly and secondary operations. Same mould, same grade, only the assembly method changed and the part stopped cracking - which means the variable was never the material. Most cracking disputes on interior and exterior parts, the kind handled under interior and exterior component testing, end up in one of these four rows that nobody recorded.
One more item is easily missed: annealing or drying changes dimensions, especially on hygroscopic materials. Relieving stress by annealing is not a free action - dimensions and assembly force have to be re-measured afterwards.
3. The medium does not corrode, it lowers the cracking threshold
The mechanism is simple. The medium enters the surface, lowers surface energy, and makes crazes open more easily. Crazes joining up become a crack.
None of this requires a measurable mass change or visible swelling. So "no deformation and no discolouration after soaking" is not a criterion - both are clean in the early stage of cracking.
Three families of media behave very differently:
| Medium family | How it acts | Where it appears | What to watch |
|---|---|---|---|
| --- | --- | --- | --- |
| Solvent type (alcohols, ketones, esters, cleaners) | Swells and lowers surface energy, acts fast | Assembly cleaning, label adhesive, pre-coating wipe | Whitening or tackiness after soak, cracking from edges |
| Surfactant type (detergents, hand sanitiser, sunscreen) | Enters craze tips, acts slowly at a low threshold | Daily wiping and handling of interior parts | Nothing short term, cracking after repeated contact |
| Oils and working fluids (fuel, engine oil, coolant, urea) | Acts together with temperature, locally concentrated | Engine bay, underbody, around filler necks | Invisible at room temperature, appears once heated |
Two media appear on no reagent list at all: residues of release agent and cleaning solvent (on the part, not on the list), and assembly consumables such as threadlocker and sealant. Anaerobic threadlockers bring out stress cracking more readily on amorphous materials, and they are usually chosen by the assembly plant without telling the material side.
Time and temperature have to be written together. The same medium shows nothing at room temperature and acts quickly once heated; conversely, lower the stress level and the tolerable time lengthens. It is one simultaneous condition - reading any single term alone gives a wrong conclusion.
The reagent list itself is set by mounting location and is covered separately (how chemical load is tested), so it is not repeated here.
4. How to catch it before the small batch
Three steps, in order.
First, a stressed specimen. Apply a known constant strain to a specimen - a bending rig or four-point loading as in the ISO 22088 family for environmental stress cracking - and immerse it in the target medium. Read initiation time and critical stress, not appearance after the soak. Only numbers obtained this way can be compared with the stress values from structural simulation.
Second, map the stress before choosing test points. Inspect moulded parts under polarised light and look at fringe density; dense bands mark the candidate crack sites. Write those locations into the test plan instead of cutting a random flat coupon - a coupon whose result does not match the part is a common waste in this kind of evaluation.
Third, read the fracture surface. The three failure types differ enough to separate:
| Feature | Stress cracking | Overload | Thermal stress cracking |
|---|---|---|---|
| --- | --- | --- | --- |
| Origin | Surface, at a stress concentration | Mid-section or at a defect | Wall step, around inserts |
| Plastic deformation | Almost none | Whitening, elongation, necking | Slight |
| Crack pattern | Several parallel fine cracks along stress | One dominant fast crack | Along thermal gradient or weld line |
| Trigger | Medium plus residual stress plus time | Single overload event | Thermal cycling, uneven cooling |
One supporting check: put uncracked parts from the same batch under polarised light. If dense fringes coincide with the crack site, the cause is residual stress, not a wrong choice of medium.
5. Corrective sequence: relieve stress first, then discuss material
Get the order wrong and every step is paid for twice.
Locate the initiation site, identify the stress source there, then relieve it: adjust gate position and injection parameters, even out wall thickness, add transition radii, reduce interference and boss hoop stress, anneal where needed. After this, most parts stop cracking.
Only if that is not enough does a grade or material change come in. The cost has to be stated up front: shrinkage differences require mould changes, environmental and chemical tests are repeated, and approval documents are revised. And if the stress source is untouched, the crack often reappears in the same place after the switch - by then the money is spent.
One rule: change structure before process, change process before material. Annealing and parameter tuning are process, gate and wall changes are structure, a grade change is material - walking up that staircase, cost increases at every step.
6. A few plain words
State three things when submitting samples: how the part is moulded (gate position, whether it is annealed), where it is mounted, and what it will contact. Those three decide which stress rig is used, which medium is applied, and which quantity is read. Miss one and the laboratory can only run a conventional chemical resistance test, and the report will not answer your question.
A chemical resistance report and a stress cracking evaluation are two different documents. When an OEM reviews a report it asks "will this location crack", not "does the material resist this reagent". Answer the wrong question and the report will not clear review however tidy it looks.
At TMC LAB this kind of commission starts by fixing the loading and medium combination from the initiation site and the assembly method, and the verdict is written as comparable quantities - initiation time, critical stress - rather than "no abnormality". Compression set and media swelling on the seal side are a separate chain (why seals leak); elastomers and rigid plastics are judged differently and should not be mixed. Routine material testing and the failure analysis route are set out under material testing.
Scheduling is arranged per project; you can state your expected delivery date when submitting samples, and we will confirm a feasible plan against the current schedule and report progress at each milestone.