Key takeaways
A domain controller's case temperature is ambient temperature plus power dissipation times thermal resistance, and an environmental test only fixes the first term. Power cycling and temperature cycling move temperature in different places, so their cycle counts are not interchangeable. Interface material degradation is visible only through junction temperature and throttling events - a chamber reading will never show it.
Write only the chamber temperature into a domain controller test report and roughly half of the stress is missing - a high-compute SoC generates its own heat. The same chamber and the same temperature profile produce two different tests depending on whether the part runs idle or at full load: the stress on the thermal path, the failure site and the acceptance criteria all change. Separate the two heat sources first, and the outline stands up. Skip that step and the report holds one chamber reading and nothing that maps to a failure.
1. Two heat sources: the chamber only covers one
The temperature condition in an environmental test is the climate class assigned to the mounting location, and it describes the air around the part. That line lives in the ISO 16750 climate clauses; how conditions are chosen against a location is covered in the five parameters behind a climate clause.
The point is that a domain controller's case temperature is not the chamber temperature. It is roughly ambient plus power dissipation times the thermal resistance along the path - the first term comes from the chamber, the second from the operating mode.
Two very different tests therefore appear under one profile. Same chamber, part idle: the die barely heats. Same chamber, part at full load: junction temperature is pushed up by the part itself. The first examines how materials tolerate ambient temperature. The second examines whether the thermal path can move heat out at all.
Conclusion: an environmental test fixes only half of the boundary condition. The other half belongs in the load column of the outline. Leave it blank and the profile is detailed but incomplete.
| Dominant heat source | Test form | What the report must state |
|---|---|---|
| --- | --- | --- |
| Ambient, unpowered or lightly loaded | High-temperature storage, temperature cycling, thermal shock | The state the sample was in during the profile (powered or not, load level) |
| Self-heating, powered and running | High-temperature operation, temperature rise measurement, power cycling | Operating mode, load profile, monitoring points and measurement method |
| Both combined | Operating temperature together with a climate profile, combined testing | Order of combination, online monitoring items, decision points |
Which items are powered and which are not has already been separated in high-temperature storage versus operation. This article covers what is specific to a domain controller: its self-heating is large enough to change the failure mechanism along the whole thermal path, so this is not a detail about whether power is applied.
2. Power cycling and temperature cycling move temperature in different places
These two are often treated as two spellings of one test. They are not.
In temperature cycling the whole sample follows the chamber, the excursion is imposed from outside, and the damage runs along thermal expansion mismatch - solder joints, leads, potting, connectors, seals. In power cycling the chamber can be held constant while the die heats and cools itself; the excursion is confined to the short path from die to substrate, the time constant is far shorter, and failures sit in the die attach and bond interfaces.
| Item | Temperature cycling | Power cycling |
|---|---|---|
| --- | --- | --- |
| Where temperature moves | The whole sample, with the chamber | The short path from die to substrate |
| Driver | External excursion and ramp rate | Junction swing and duty cycle |
| Typical failure site | Expansion mismatch interfaces, seals, connectors | Die attach, bond interfaces, interface material |
| What the report needs | Profile, dwell and cycle count | Junction and case temperature curves, switching rhythm |
The difference between external profiles - why cycling and shock cannot cover each other - is in temperature cycling versus thermal shock. The point here is a different layer: even with an identical external profile, how far the junction actually swung may not appear anywhere in the report.
A report that says "temperature cycling, a given number of cycles" cannot answer how large a swing the die attach experienced. That swing is the fatigue driver for that layer. Adding cycles does not close the gap either - more cycles at the wrong amplitude simply exercise a different mechanism.
3. Interface material degradation is a materials item judged away from temperature
Split the thermal path and three links appear in series: the die attach, the thermal interface material, and the substrate with its solder joints.
Their degradation modes differ. The die attach suffers thermal fatigue and void growth. The interface material suffers pump-out, dry-out and delamination. Substrate and joints suffer expansion fatigue and cracking. All three show up as one thing: rising thermal resistance.
| Link | Degradation mode | Evidence visible in the report |
|---|---|---|
| --- | --- | --- |
| Die attach | Thermal fatigue, void growth | Case-to-junction difference grows at the same load |
| Thermal interface material | Pump-out, dry-out, delamination | Thermal resistance rises, throttling events increase |
| Substrate and joints | Expansion fatigue, cracking | Resistance drift before and after, local hot spots |
Once resistance climbs, junction temperature rises at the same load, throttling or protection engages, and behaviour changes: compute drops, the display stutters, communication times out.
The key point: none of this moves the chamber temperature by a single degree. The chamber curve looks normal, the part is not dead, and the report says the function was normal - while the thermal path has already degraded. Only three things reveal it: the case-to-junction difference at the same load, the count of throttling and protection events, and a resistance comparison before and after the test.
One boundary worth drawing. Insulation problems that a domain controller develops under damp heat or condensation follow moisture plus bias ion migration - an electrical path, investigated along that chain, not the one described here. That one is corrected by humidity control, cleaning and coating; this one by interface material, mounting pressure and heat sink design. Potting compound plays both roles - a sealing measure and a link in the thermal path. Sealing verification is covered under ingress protection testing, but change the potting and the thermal resistance has to be measured again.
4. Four columns in the outline, and three traps
For a part like this, four items deserve their own columns:
- Load profile: how much time at idle, nominal, full load and burst; who supplies the program and which revision it is.
- Monitoring points and method: junction temperature from an internal sensor or extrapolated from the case, where the sensor is bonded, what the sampling interval is.
- Acceptance basis: whether degradation is allowed, whether throttling counts as a failure, whether recovery must be reversible. The public definition of functional status is in GB/T 28046.1; cite it rather than restate it.
- Before-and-after comparison: thermal resistance, quiescent current, functional self-check, appearance, and cross-sectioning where needed.
Three traps, each more expensive than the last:
First, chamber temperature without a load. Two parts run to the same profile, one idle and one at full load, produce results that cannot be compared, and afterwards nobody can tell whether the difference came from the sample or from the outline.
Second, treating throttling as protection and not as failure. Throttling is the die protecting itself, not a certificate of conformity. The acceptance basis has to be agreed in advance, or the same data reads as "protection worked" on one side and "function degraded" on the other.
Third, a power-on check as the only post-test step. Thermal path degradation is gradual. A normal power-on check does not mean resistance has not drifted; skipping the comparison closes the only window that shows it.
When three stresses run together - temperature, humidity and vibration - the heat source column still cannot be dropped. How to combine and trim them is in combined testing and the environmental test checklist. For cases that pass on the bench and throttle in the vehicle, the four gaps reviewed here are a useful cross-check.
A few plain words
The value of a domain controller report is not in how elegant the profile looks, but in whether the operating mode is written in enough detail. One chamber, two outlines - with and without a load profile - is two entirely different reports.
When TMC LAB takes on this kind of commission, the load profile, monitoring points and the acceptance basis for permitted degradation are confirmed first, and only then are the temperature profile and cycle arrangement set. Degradation of materials and the thermal path is judged from before-and-after readings, with no values preset before the test. Conditions and limits follow the standard text, the customer specification and the technical agreement.
Sending the heat sink design (fan, thermal pad, metal bracket), the actual load program and the permitted degradation basis together with the samples lets the outline be aligned in one pass and avoids rework mid-test. Scheduling is arranged per project; you can state your expected delivery date when submitting samples, and we will confirm a feasible plan against the current schedule and report progress at each milestone.



