Skip to main content
  1. Home
  2. Technical Blog
  3. Environmental Reliability
  4. How to Read a Random Vibration PSD - Four Readings per Curve, and Why Matching Grms Is Not the Same Test

How to Read a Random Vibration PSD - Four Readings per Curve, and Why Matching Grms Is Not the Same Test

Key takeaways

A PSD in g²/Hz is a density; integrate it over frequency and take the square root to get Grms - the first is shape, the second is area. The same Grms can describe a spectrum pushed toward low frequencies (large displacement demand) or toward high frequencies (more cycles), attacking different failure families. Read a report in the order response spectrum, control spectrum, tolerance and interruption records; miss one and comparability drops.

The height of a PSD curve says nothing about how severe a test is. A random vibration spectrum is defined by two things: how much energy there is, and which band it sits in. The first is Grms, the second is spectral shape. Two spectra with identical Grms but different shapes will produce different failures on the same part. Reading a PSD is therefore not about whether the curve looks like a mountain; it is about knowing whether the number in your hand is a density, a total, or a response.

1. A PSD is a density, not an amplitude

The unit gives it away: g²/Hz, mean-square acceleration per hertz of bandwidth. It is a density.

Integrate it over frequency and you get the total mean square; take the square root and you have Grms. Grms is an area; the PSD is a shape.

Two common habits fail as soon as that relationship is on the table:

  • comparing the Grms of two spectra to decide which is stricter, which compares total area rather than where the energy sits;
  • judging severity from the height of the curve at one point, which is the density inside a single hertz and changes the moment the bandwidth scale changes.

The other side matters just as much: random vibration has no single amplitude. A sine test can be written as a stated acceleration at a stated frequency; a random test can only be described statistically. A pass criterion therefore cannot be phrased as a peak value, only as whether function is retained and whether structural degradation is detectable at a given level for a given duration.

2. Four readings on one curve

Work through these four in order and you can tell what the spectrum is really testing.

ReadingThe question it answersWhat goes wrong if misread
---------
Frequency range (lower and upper limits)Which modes the spectrum coversToo high a lower limit leaves the rigid-body mode of a heavy part outside the excitation; too low an upper limit skips board-level and solder-joint modes
Spectral shape (flat and sloped segments)Which band carries the energyJudging by level alone treats a relocation of energy as the same test
Overall GrmsHow much total energy there isComparing two spectra on this number alone is judging height by body weight
DurationHow long damage accumulatesDuration and level are a bound pair and cannot be swapped at will

The frequency range is the one most often skipped, because it is not in the title, only in the start and end of the horizontal axis.

It is also decisive: a spectrum only means something if it covers the modes of the part. Energy that falls outside the modes produces little response; conversely, modest energy sitting on a resonance can drive local stress far beyond expectation, with amplification set by damping.

3. The same Grms can be two entirely different tests

Acceleration spectra do not convert to displacement linearly: displacement density scales with acceleration density divided by frequency to the fourth power, velocity by frequency squared. Move the same total energy from a high band to a low band and Grms can stay unchanged while the displacement demand multiplies.

Shape differenceGrmsDisplacement demandWhat it mainly attacks
------------
Energy pushed toward low frequenciesCan be identicalClearly largerHeavy mounts, brackets and harnesses: displacement limits, rubbing, fatigue
Energy lifted toward high frequenciesCan be identicalClearly smallerBoard-level and solder-joint stress cycles, more cycles in the same duration
Narrow band on one modeCan be identicalDepends on the mode shapeThe local structure of that mode; response set by damping and amplification

All three rows say one thing: matching Grms means matching total energy, not matching where the energy lands.

The third row also implies a reading habit. Modal frequencies drift with temperature, assembly preload and ageing. The spectrum is fixed; the modes of the part are not, so the same condition run at a different stage may excite a different location.

4. Three places in a report that prove the spectrum was actually run

A correct spectrum plot does not make a correct test. Three things have to be answerable, and each missing one discounts comparability.

Control spectrum and response spectrum are different readings. The control point normally sits at or near the fixture and table and reports what the machine achieved; response points are on the specimen and report what the specimen received. A control spectrum alone proves the equipment was compliant, not how the specimen was excited.

Look for tolerance and out-of-tolerance records. Random vibration approaches the target by closed-loop control, so deviation always exists. A report should show measured against target spectra, the in-band and out-of-band verdict, and what was done when limits were exceeded: derating and restarting versus interrupting and extending are written very differently and carry different weight.

Interruptions and cumulative duration must be stated. Random vibration accumulates damage over time, and stopping, re-clamping or replacing a sensor all change how time is accumulated. A report that gives only a total running time, with no interruption record, gives a figure that cannot be traced.

Clamping, axes and fixture stiffness belong upstream, to how conditions are derived, and are covered in the ISO 16750-3 mounting-location breakdown. Choosing between sine and random is a separate question: sine answers where a structure is weak, random answers how long it survives, and the division of labour between them is treated separately.

A few plain words

The hard part of reading a PSD is not the arithmetic; it is knowing which question the number answers.

  • Read the frequency range first and confirm the modes are inside it;
  • then read the shape and see which band carries the energy;
  • treat Grms as a total, never as a severity index;
  • in the report, read the response spectrum, then the control spectrum, then tolerance and interruption records.

For slender and flexible parts such as harnesses, pipes and jumpers, failure under random vibration concentrates at restraints and terminals; the harness vibration article covers restraint simplification and observation items for that family. When random vibration has to be applied together with temperature and humidity in one chamber, combined-condition layout is a different thread.

For the spectra and tolerances published in the standards, start with the clause breakdowns on the GB/T 28046 and ISO 16750 pages; the correspondence between the two series is treated in a separate article, and the mechanical-load conditions sit in the same cluster. TMC LAB writes control-point location, response-point location, tolerance judgement and interruption handling into the test outline, so the spectrum plots in the final report have something to be checked against.

Which axis to use, how to clamp and where to place monitoring points follow from the structure and its mounting state; the vibration service scope and the trimming logic for a full test set are described in the environmental reliability checklist.

Scheduling is arranged per project; you can state your expected delivery date when submitting samples, and we will confirm a feasible plan against the current schedule and report progress at each milestone.

Related Q&A

Related questions

Frequently asked questions on the same topic. The first paragraph of each answer is the conclusion.

If two random vibration tests have the same Grms, are they the same test?
No. Grms is the integral of the PSD over the band, square-rooted; it captures the total energy and nothing about its distribution. The same Grms can describe a spectrum pushed toward low frequencies or one lifted toward high frequencies - the first demands more displacement, the second produces more stress cycles, and they attack different failure families. To decide whether two spectra are the same test, compare four items: frequency range, spectral shape, overall level and duration. Match on three and the equivalence does not hold.
Should I look at the control spectrum or the response spectrum in the report?
Both, and in the order response first, control second. The control point sits at or near the fixture and table and shows how closely the machine achieved the target; the response point is on the specimen and shows how much excitation the specimen actually received. A control spectrum alone only supports the statement that the equipment was compliant; a response spectrum with the control spectrum out of tolerance equally fails to support a conclusion. A proper report presents both spectra together with the tolerance verdict and the record of what was done when limits were exceeded - check those three and you can judge whether the data supports a before-and-after comparison.
What does dB/oct mean on a PSD plot?
It describes how fast the spectral shape rises or falls - how many decibels the density changes each time the frequency doubles. A flat segment has a slope of zero, meaning equal energy per hertz across that band; rising and falling segments are labelled in dB/oct so the shape can be reproduced rather than traced by eye. Two things to watch: the break frequencies where sloped and flat segments meet, since these are usually the boundary of concentrated energy; and the fact that on a logarithmic frequency axis, visual steepness does not map exactly to the labelled dB/oct, so read the value instead of judging by eye.

These answers share the same data source as the FAQ page.

Have a testing requirement? Send us your product details

Tell us the product model and test requirements. Our engineers will map out the test plan, the applicable standards and the item combination, and provide a quotation reference. The more specific the request, the sharper the answer.

  • Free scoping of the test plan and standards
  • Pre-scan testing during R&D to cut rework cost
  • On-site visits and witnessed testing supported
  • Scheduling per project, with progress updates at each milestone

Received — we will contact you shortly and follow up with a test plan and quotation.

By submitting you agree to be contacted by phone or email. Scheduling follows the project’s actual availability and is subject to mutual confirmation.

13510907826
Call