Key takeaways
The first cut in failure triage is not which component failed, it is whether this was a single overload or accumulated damage. The criterion sits on different quantities: overload reads the peak, accumulation reads cycles and dose. Five readings separate them - gross deformation, origin and propagation marks, alignment with an event, position and batch distribution, parameter history. Accumulation runs on separate ledgers: cycle count, temperature times time, relative slip count, charge and moisture time, load cycles and preload. Running a test longer only turns the ledger faster, it does not swap the ledger. Classify it wrong and the fix lands on the wrong end: overload needs the peak lowered, accumulation needs cycles or temperature lowered, and adding a protection device does nothing for fatigue.
The same word crack can mean a part that could not survive one peak, or a part that used up its margin over hundreds of reversals. The two paths leave different marks, and they demand opposite fixes: one lowers the peak or changes the path, the other lowers cycles, temperature or changes material. Draw that line wrong and the report can be immaculate while the fix lands on the wrong end - and a corrective action that has to be reversed costs more than getting the line right once.
This article is about where that line goes: which quantities to read, and in what order, between "the part failed" and "this is the class of failure". The mechanisms themselves - temperature cycling versus thermal shock, which layer a solder joint fails in, how a via barrel fatigues - are treated elsewhere.
1. Two paths: same symptom, opposite directions
Single overload means one load exceeded what the part could carry, or one transient pushed a local region past its limit. Its signature is that once was enough.
Accumulated damage means every load sat far below the limit, but each left a small irreversible change, and the sum reached critical. Its signature is that no single event was enough.
What separates them is not severity but which quantity the criterion sits on: overload reads the peak, accumulation reads cycles and dose. Take the same cracked bracket. If it cracked after one mis-operation, the question is what that operation applied. If it keeps coming back in the same location under the same duty, the question is the load cycles and the constraint in that span.
Morphology gives a direction and no more. Overload also starts at stress concentrations, and accumulation often shows a single origin. Brittle parts and small joints such as solder barely deform under overload at all. So the fracture is corroboration only; the readings come next - and whether a joint failed at the pad or in the bulk alloy is a separate question in itself (fracture location by interface).
There is a prerequisite that gets skipped: temperature cycling and thermal shock are not two speeds of the same ledger, and mixing them reverses the triage (cycling and shock are not fast and slow).
2. Five readings that put the part on one side
Once the part is on the bench, do not cut first. The five readings below come from a stereo microscope and the records, cost little, and check each other.
| Reading | Points to single overload | Points to accumulated damage |
|---|---|---|
| --- | --- | --- |
| Gross deformation and dimensions | Visible bending, necking, whitening, an elongated hole | Shape and fit are largely preserved, dimensions unchanged |
| Origin and propagation marks | Single origin, radial pattern, large final fracture zone | Multiple origins, or one at a stress concentration, with a front and several arrest marks |
| Alignment with events | Lines up with one event: drop, misconnection, stall, short overload | Lines up with nothing single, only with total count, time or exposure |
| Position and batch distribution | Scattered with handling and assembly position | Clustered in one mounting location, one duty, one hot zone |
| Parameter history | Step change: one jump past a threshold | Monotonic drift: contact resistance, leakage, threshold moving slowly |
Parameter history is often skipped and it resolves a lot. A part that was fine until suddenly it was not, and a part that slowly became not quite right and then failed, are two different cases. The first sends you to one event; the second sends you to a stretch of time. If line-end test data, repair records or vehicle logs exist, this reading answers earlier than any fracture does.
When the five readings disagree, trust the one aligned with an event, then look at drift. Events can be verified; drift can only be inferred from history. If neither lines up, the part probably took a combined path - see section 4.
Passing the readings is not yet a conclusion. Whether they support one is a separate layer (four tests: sequence, dose, reproduction, alternatives). Classify first, then argue about strength.
Before cutting, image first: look for a second origin inside before deciding where the section goes (X-ray and CT inspection).
3. Accumulation runs on separate ledgers
Landing on the accumulation side is only half the answer. The next split is which ledger is being written, because the ledger decides what makes it run faster and which reading carries the criterion.
| Ledger | What it records | How it shows in the field |
|---|---|---|
| --- | --- | --- |
| Cycle count | Reversals of temperature or load, with amplitude per cycle | Solder, pins and bond wires crack at interfaces; failure tracks cycle count |
| Temperature times time | Temperature level and dwell | Seal compression set, plastic creep, insulation hardening or softening |
| Relative slip count | Slip events and amplitude between contact surfaces | Contact resistance creeping up; plating worn through into corrosion |
| Charge and moisture time | Charge passed under bias, humidity and condensation time | Insulation resistance falling, dendrites growing, tracking along the field |
| Load cycles and preload | Mechanical cycle count and preload decay | Bracket cracking, threaded joints loosening, ground resistance rising |
All five share one property: none can be hurried, they are only traded for count, time or dose. That explains something simple - running a test longer only turns the ledger faster, it does not swap the ledger. Raise the vibration level and the cycle-count ledger turns faster; raise the temperature and the temperature-times-time ledger turns faster. Which ledger is driving the failure is set by the part and its duty, not by the equipment.
One ledger is often not enough. A connector in a temperature cycle writes two at once: terminal fretting records relative slip, the seal records temperature times time. Which quantity carries the criterion decides whether that test can ask the question at all - measure only contact resistance and nobody reads the seal's ledger (via barrel fatigue is the same cycle-count ledger).
The migration and corrosion ledger needs three things at once: field, moisture and time. Remove any one and it stops, which is why in the field it looks like "the parts facing that way fail first" (migration follows the field).
The ledger also sets how far results extrapolate. Acceleration changes the page-turning rate, not the ledger; the reach of an extrapolation is set by mechanism, not by equipment power (test hours are not service years). Vibration is the clearest case: one overall level can correspond to two entirely different spectra (which numbers to read in a PSD, vibration testing).
4. Classify it wrong and the fix lands on the wrong end
Triage is not taxonomy. It decides where the next action goes. These four groups match what actually happens in review meetings.
| Classification | What to fix first | The usual wrong move |
|---|---|---|
| --- | --- | --- |
| Single overload | Lower the peak, change the path, add clamping and protection, change handling and assembly | Harsher testing, or a more expensive material straight away |
| Accumulation: fatigue | Lower amplitude and cycles, reduce stress concentration, use a more ductile material or joint | Adding a protection device, which does nothing for fatigue |
| Accumulation: thermal and ageing | Lower temperature, improve the thermal path, raise the temperature rating, shorten hot dwell | Changing vibration or mechanical items - wrong direction |
| Accumulation: migration and corrosion | Lower field strength, widen spacing and creepage, control humidity and sealing, clean residues | Coating over uncleaned residue and sealing it in |
The fix follows the class of failure, not its severity. A badly burnt part does not imply a protection device; a single hairline crack does not imply a small problem. Review meetings produce this mismatch constantly: the report says severe damage, and the first line of the action list adds a component.
The second mismatch is changing only one thing. A part often runs two or three paths at once; one drives the failure, the others only move the threshold.
| Role | How it is identified | How to treat it |
|---|---|---|
| --- | --- | --- |
| Primary | Remove it and the failure stops | Must be fixed, and verified by the phenomenon disappearing |
| Contributing | Not sufficient alone, but lowers the threshold for the primary | Fix it as well, or the same batch returns later |
| Consequential | Another result of the same event, not a driver | Label it separately; do not fix it as a cause |
Three things separate the roles: comparison, sequence, dose. Change one thing and see whether the phenomenon goes - that is primary. Earlier in time but insufficient alone - that is contributing. Present at the same moment yet changing nothing when removed - that is consequential. Assembly stress is the classic contributing factor: it does not crack anything by itself, but it lowers the fatigue threshold (assembly stress borrows life before the test). The classic misread consequence is arc melting from a short: a result, not a cause.
Role and confidence are two different questions. Which path drives the failure is about mechanism; how strongly the conclusion can be stated is about evidence (how to write it when reproduction is impossible). Written separately, the report survives the follow-up.
Draw the line on the conditions side as well. GB/T 28046 and ISO 16750 supply applied conditions and functional status grades, not failure classification. A standard can state under what conditions a part failed; it cannot say whether this was one overload or an accumulation. Treating a clause as a conclusion is the usual drift in this kind of report.
5. A few plain words
Half the information needed for triage lives outside the laboratory.
Three items on the request form are enough: what the part went through (which events, how many, how long), whether non-failed parts from the same batch are available for comparison, and whether the failure was a step change or a drift. Without them the laboratory reconstructs everything from the fracture, and the direction it reconstructs can be exactly backwards.
Two things not to do: do not bend the deformation back, and do not finish the whole test run after a failure is found. Later loads overwrite earlier marks, and the event that would have aligned is gone.
Get the triage right and the corrective action has somewhere to land. When TMC LAB takes on a failure analysis request, the first split is always single overload versus accumulated damage, before any decision about where to cut, so the question is not discovered after the section is already made.
Scheduling is arranged per project; you can state your expected delivery date when submitting samples, and we will confirm a feasible plan against the current schedule and report progress at each milestone.