Skip to main content
  1. Home
  2. Technical Blog
  3. Failure Analysis
  4. Where a Solder Joint Breaks Matters More Than Whether It Broke - IMC, Pad or Bulk Solder Point to Three Different Fixes

Where a Solder Joint Breaks Matters More Than Whether It Broke - IMC, Pad or Bulk Solder Point to Three Different Fixes

Key takeaways

The judgment on a solder joint should not stop at "it broke"; it has to land on which layer it broke in. A break inside the board-side intermetallic, a break between pad and laminate, and a break along grain boundaries in the bulk solder map to three entirely different stresses - thermal process, mechanical bending, and thermal cycling - and are fixed in the process window, in structure and assembly, and in joint geometry and condition design respectively. A passed electrical test is not evidence of an intact joint: a micro-crack usually still conducts at room temperature and static load, so three lines of evidence have to agree - resistance monitored while stress is applied, dye penetration, and cross-section observation.

The first question after a solder joint breaks is usually whether the alloy lot was bad. What carries more information than whether it broke is which layer it broke in. A break inside the copper-tin intermetallic means the interface embrittled, which follows high-temperature storage, repeated reflow and repeated rework. A break between pad and laminate means the board was bent - a structural and assembly stress. A break along grain boundaries in the bulk solder means thermal cycling fatigued the joint. The three look different, appear at different times, and are fixed by changing the process, the structure, or the joint geometry respectively. The directions do not transfer.

1. A joint is not one body; a fracture crosses five layers

The path from component termination to board runs through five layers in series. Where the fracture sits tells you which segment of that path was pulled apart.

LayerWhat it isWhat a break here points to
---------
Termination finishEnd metallisation, commonly tin, nickel or silver-palladium systemsThe component or its termination process, not the assembly house
Component-side interfaceCompound formed by reaction between termination metal and solderEmbrittlement on the component side, often thin finish or poor solderability
Bulk solderThe alloy body joining both sidesFatigue or mechanical overload; look for striations
Board-side interfaceCompound formed by copper and tin, commonly two phases coexistingPad condition, reflow profile, storage temperature
Copper pad and laminateCopper foil and resin substrateThe board failed first, i.e. pad cratering, a bending problem

Of these five, the interface layers are generated by reaction rather than purchased. They thicken with temperature and time, accumulate with each reflow, and keep growing during storage. The state of the interface is therefore a record of the thermal history that board has seen.

Both sides grow an interface, but the metals differ and so do the growth rates. That is why on one board some designators break on the board side and others on the component side - they are not the same event.

In one line: the fracture does not happen "in the joint", it happens in one of these five layers.

2. Three fracture locations, three sets of corrective actions

Grouping the common fractures by location gives four classes, each with its own dominant stress, appearance and starting point for correction.

Fracture locationDominant stressAppearanceCorrective action starts at
------------
Inside the board-side interfaceHigh-temperature storage, repeated reflow, accumulated reworkFlat, dark, almost no plastic deformationReflow window, rework count limit, storage conditions
Between pad and laminateBoard bending, screw torque, insertion force, inertia of heavy partsResin and copper foil residue, often starting obliquely from a component cornerStructural support, assembly operations, component layout
Along grain boundaries in bulk solderExpansion mismatch under thermal cyclingStriations, starting at the fillet root, may stop part wayJoint geometry, component size, condition design
Component-side finish and interfaceThin termination finish, contamination, poor solderabilityBreak on the component side with the board joint intactIncoming component, finish system, solderability verification

A break inside the board-side interface is the one most often misread as bad solder. The fracture shows almost no deformation, looks brittle, and the conclusion follows that the alloy is brittle. But the interface layer is itself a brittle phase; once it grows thick enough the interface becomes brittle as a matter of course, which is a different statement from whether the alloy was acceptable.

One location inside that layer deserves attention: voids can cluster near the boundary between copper and compound, an effect associated with element diffusion at elevated temperature, appearing as a row of small voids forming a weak plane. A fracture there means the thermal history had already hollowed out part of the interface, and the break was not created by bending during assembly.

A break between pad and laminate means the stress entered from the board side. The typical form starts obliquely from a component corner, and the section shows laminate fibre and copper foil residue. It has little to do with joint strength - the joint may be perfectly intact while the board underneath it failed.

The stress sources are specific: snapping and router push during depanelling, uneven screw torque, a board pushed into bending during connector insertion, inertia of heavy components under vibration and shock. The way to judge this is not the fracture surface but the designator map: does the failure cluster around a hole, a depanelling line, a connector.

A break inside the bulk solder is the real fatigue case. It follows grain boundaries, initiates at the high-strain region near the fillet root, and usually appears on several joints in the same area at once. This kind of fracture takes time - each thermal cycle converts expansion mismatch into plastic strain, accumulating until a crack initiates and then propagates to separation.

Its location correlates strongly with geometry: taller joints and steeper fillets concentrate strain at the root; larger components further from the neutral point impose a larger displacement per cycle. Correction therefore lands on geometry and conditions, not on an alloy grade.

3. Electrical test passes it because a micro-crack still conducts

This is where the failure mode slips through.

Before a crack goes fully through, the two faces still touch, and the DC resistance shift falls inside reading noise. A multimeter or an in-circuit test reads a good joint. By the time it opens completely, the symptom is loss of function, and everything between those two states has lost its information.

There is a subtler variant: the broken net has a parallel path elsewhere, such as multiple ground points or a second return for the same signal. One point opens, the circuit still works, the test still passes, and the problem only surfaces when the second path also degrades.

Forcing the fracture out takes three lines of evidence crossing; any one alone is not enough.

MethodShowsDoes not show
---------
X-ray projectionVoids, ball diameter, offset, bridgingAn interface that touched without coalescing; a separated crack whose faces still contact
Dye penetrationWhich ball, which face, has separatedThe cause, and when it happened
Cross sectionWhich layer the crack sits in, interface morphology, voidsWhole-board distribution; only the joints that were cut
Resistance monitoring during exposureAt which cycle or moment the open occurredWhich layer broke
Acoustic scanningInterfacial delamination, package internalsLimited resolution on fatigue cracks in joints

The one worth planning in advance is monitoring during exposure. It converts "did it break" into "when did it break", and the timing is exactly what separates the stresses - breaking in thermal cycling points to fatigue, breaking under vibration points to mechanical load, breaking in both means two chains are active and both have to be addressed.

One clarification: a joint fracture and a component body crack are different events. The flex crack and thermal crack in a ceramic capacitor sits inside the component, with different morphology and a different fix; delamination and popcorn under moisture plus fast heating sits at the laminate interface and is not a joint either. Merging the three in a report leaves the reader with no place to act.

4. Four ways to misread a fracture

First, treating one X-ray as a conclusion. A projection is a superposition; the difference between an interface in contact and one truly coalesced is almost flattened out. Use it to locate, not to classify.

Second, prying the sample apart before protecting the fracture. Levering during disassembly superimposes fresh tearing on the original surface, and every later judgment rests on contaminated evidence. The order is dye first, then pry, then section. Reversed, the evidence is destroyed.

Third, grinding and polishing the crack away. Solder is soft and the interface layer is thin, so grinding drag and over-polishing smear fine cracks or wash out the residue inside them. That residue is often exactly where the elemental information lives.

Fourth, leaving rework records out of the analysis. A reworked joint has a thicker interface and coarser grains, and its fracture location shifts toward the interface as a whole. Without knowing the joint was touched up, the added thermal history is easily misread as a poor incoming interface.

5. A report needs four columns, an outline needs four items

The output of a failure analysis is not the sentence "the joint fractured"; it is a chain of evidence with four columns complete.

ColumnWhat goes in itConsequence if empty
---------
Fracture locationSection photograph, layer names annotated, designatorThe conclusion cannot be reproduced or compared with siblings
Fracture appearanceTransgranular or intergranular, striations, voids, finish residueFatigue cannot be separated from overload, brittle from ductile
Composition and phasesEDS elemental result, interface phase makeup and thickness trendContamination, finish anomaly and normal alloying cannot be told apart
Stress attributionMapped to a specific process step or stress typeNo place to act; the report ends at "strengthen quality control"

In the test outline, four items must be explicit: sample state (whether reworked, how long stored), exposure and monitoring (cycle type, monitored quantities, sampling capability), acceptance items (functional status, resistance change, event count), and retention and sectioning rules (which joints are kept for sectioning, in which direction).

Conditions and acceptance follow the customer technical agreement and the board-level acceptance document. GB/T 28046 and ISO 16750 provide the environmental condition framework at the part level, and LV 124 provides the exposure framework for automotive electrical parts; none of them specifies which layer a joint should break in, nor an acceptable interface thickness. Board-level acceptance usually rests on industry board-level standards and customer drawings, with specific clauses following the controlled version.

On the test side, temperature cycling and vibration are the natural companions, and bending and peel items under materials and processes cover the resistance of board and joint. They are there to reproduce, not to classify. Classification still comes from the section.

A few plain words

First, do not treat a fracture surface as a verdict. In one batch of failed parts it is common for half to break at the interface and half at the pad, which means two stresses were present at once, not that the whole batch was bad.

Second, different designators breaking in different layers on the same board is valuable information. Do not compress it into "multiple joint fractures". It says two things happened simultaneously, and fixing only one leaves the other in place.

Third, the recommended order is: fix the layer, then the stress source, then process and structure, and put the alloy grade last. Done the other way round, the usual outcome is two rounds of alloy changes with the fracture in the same place.

Fourth, underfill changes the crack path, not the stress. The fracture location moves outward, and if the mechanical input underneath is untouched, the problem merely reappears elsewhere.

TMC LAB asks for three things before starting this kind of analysis: fracture photographs with the designator map, the production and rework records for the lot, and the scenario in which the failure occurred - which test, how long in the vehicle. With all three, there is a basis for deciding which joint to cut and in which direction. Missing one, even a beautiful section yields half a conclusion. If the symptom is intermittent functional anomaly rather than a complete open, start with the reproduction path for intermittent failures; terminal crimp and insertion interfaces follow separate logic, covered in terminal cross-section judgment and automotive connector reliability testing.

Scheduling is arranged per project; you can state your expected delivery date when submitting samples, and we will confirm a feasible plan against the current schedule and report progress at each milestone.

Related Q&A

Related questions

Frequently asked questions on the same topic. The first paragraph of each answer is the conclusion.

The joint broke - is it a solder paste or alloy lot problem?
Usually not. Lot-to-lot variation in solder shows up as differences in wetting and voiding, and it tends to scatter across many designators, panels and products. Fracture location is far more directional: breaks all sitting at the board-side interface point to the thermal history of reflow and storage; clustering at board edges, screw holes and behind connectors points to assembly stress; intergranular breaks with fatigue striations point to thermal cycling. To argue incoming material, rule out these three first, not the other way round. A certificate of conformance covers composition and solderability; it says nothing about where a joint will break under vehicle stress.
X-ray showed nothing abnormal - can a joint fracture be ruled out?
No. X-ray works on density contrast and is good at voids, ball diameter, offset and bridging, but an interface where two balls touched without actually coalescing, and a micro-crack whose two faces are still in contact, both carry very low contrast in a projection image. Judging a joint needs three lines of evidence crossing: continuous resistance monitoring through thermal cycling or vibration to catch intermittent opens, dye penetration followed by prying to see which face of the ball separated, and sectioning one or two joints to see which layer the crack sits in. Missing any one of them, the conclusion can only be written as a hypothesis.
Does underfill stop joints from breaking again?
Underfill changes the crack path, not the stress. It spreads the strain at the fillet root into the adhesive interface between the fill, the component and the substrate, and in many cases that does extend life. The price is that the fracture location moves outward - from the bulk solder to the pad-to-laminate interface, or to the fill-to-component-edge interface. If the bending, screw torque and connector insertion force underneath are untouched, the problem simply reappears somewhere else, and the new cross section is harder to read. Before filling, confirm which layer is breaking, then judge whether the fill can reach that layer.

These answers share the same data source as the FAQ page.

Have a testing requirement? Send us your product details

Tell us the product model and test requirements. Our engineers will map out the test plan, the applicable standards and the item combination, and provide a quotation reference. The more specific the request, the sharper the answer.

  • Free scoping of the test plan and standards
  • Pre-scan testing during R&D to cut rework cost
  • On-site visits and witnessed testing supported
  • Scheduling per project, with progress updates at each milestone

Received — we will contact you shortly and follow up with a test plan and quotation.

By submitting you agree to be contacted by phone or email. Scheduling follows the project’s actual availability and is subject to mutual confirmation.

13510907826
Call